Form Test Please enable JavaScript in your browser to complete this form.1) Please specify the Wavebands you requireIf you are trying to match a satellite band, please advise so that we can give you the closest matchChannel 1 - CWL (nm)eg 645Channel 1 - FWHM (nm)eg 50Channel 1 - 50% cut-on (nm)eg 620Channel 1 - 50% cut-off (nm)eg 670Satellite Satellite Bandeg MODIS 1Channel 2 - CWL (nm)egChannel 2 - FWHM (nm)egChannel 2 - 50% cut-on (nm)egChannel 2 - 50% cut-off (nm)egChannel 2 - Satellite BandegChannel 3 - CWL (nm)egChannel 3 - FWHM (nm)egChannel 3 - cut-on (nm)egChannel 3 cut-off (nm)egSatellite BandegChannel 4 - CWL (nm)egChannel 4 - FWHM (nm)egChannel 4 - 50% cut-on (nm)egChannel 4 - 50% cut-off (nm)egSatellite BandegSingle Line TextCWL:        Centre Wavelength FWHM:     Full width at half maximum (the bandwidth between the points where transmittance is 50% of the peak). Whilst we aim to match requested CWL and FWHM values as closely as possible the following tolerances apply: FWHM <20nm : ±2nm            FWHM 20-50nm : ±5nm          FWHM >50nm : ±10nm2) Please specify the meter (s) or datalogger(s) you intend to useSkye Instruments' DevicesDataHog2SpectroSenseSerial number if you intend to use an existing deviceOther ManufacturerPlease supply manufacturer and model number, eg Campbell CR10003) Do you require tabulated spectral response data (SKL 185)? There is a small chargeAs standard sensors are only supplied with a graphical response curve for each channelCheckboxesTabulated data will be supplied as an Excel file4) Which calibration units do you require?µmol m-2 s-1W m-2µmol m-2 s-1 is the default option5) If you are only ordering a single sensor, which of the following do you require?Cosine corrected to measure irradiance (incident radiation)Narrow angle field of view to measure radiance (reflected radiation)6) Please advise the light intensity range you intend to measureNatural sunlight intensities (default option)Channel 1 Intensityeg 0-500 µmol m-2 s-1Channel 2 IntensityChannel 3 IntensityChannel 4 Intensity7) Do you require an extension cable?Default cable lengths are as follows: 3m     - Wire ended for connection to other manufacturer's equipment 3m     - For use with a DataHog2 2m     - For use with a SpectroSense2 or SpetcroSense2+ 1.2m  - For use with a Display or Apollo MeterIf yes please specify TOTAL length in metres8) Do you require low temperature specification cable fittedIf sensors are to be used at temperatures below -20°C, low temperature specification cable will need to be fittedLength required9) Additional InformationPlease provide us with any additional information regarding the application and location in which you will be using these sensors. This will help us to recommend the sensor configuration that best suits your requirements.Name *FirstLastAddress *Email *EmailSubmit